33Visual · Aerial Intelligence

18–20 November 2026
Mojonera Survey

Static GNSS · CSRS-PPP pending
3survey dates3mojoneras6RTK observations
All week · 18–20 November 2026
3 static sessions · 6 RTK observations
Select a mojonera to locate it on the map.
● RTK location━ Project chainage path

Static occupations

261118 · 4:00:10 static · local 10:49:56–14:50:06
RTK before 10:45:44–10:48:44 · FIX
RTK after 14:51:02–14:54:02 · FIX

261119 · 4:00:35 static · local 09:16:43–13:17:18
RTK before 09:10:47–09:15:47 · FIX
RTK after 13:18:07–13:23:07 · FIX

261120 · 4:00:17 static · local 09:36:23–13:36:40
RTK before 09:32:19–09:35:19 · FIX
RTK after 13:37:25–13:40:25 · FIX

RTK checks, antenna height and reference frame

Mojonera 3243 changed RTK reference base between checks. The reported ellipsoidal height increased by 0.464 m. Both readings were FIX. The base change affects the RTK comparison only. CSRS-PPP processes the static observations independently using precise satellite products.

The standardized static procedure provides an independent basis for future project base coordinates. The before and after RTK readings document field QC.

The RINEX header records 2.100 m from the mark to the antenna reference point. The RTK export records an antenna height of 2.234 m and identifies the coordinate system as Mexico ITRF2008 / UTM zone 14N.

Canadian Geodetic Survey · CSRS-PPP processing protocol
  1. Check each RINEX observation file
    Use one .26O per mojonera. Confirm marker identity, observation coverage, antenna model and the 2.100 m marker-to-ARP offset against the setup record. Verify the antenna calibration applied by CSRS-PPP.

  2. Submit as Static in ITRF
    Use the Canadian Geodetic Survey CSRS-PPP portal. Select Static and ITRF for the Mexico sessions. Retain the reference frame and coordinate epoch returned by the service. NRCan lists IGc20, a realization of ITRF2020, for these observation dates.

  3. Keep the complete solution
    Archive the returned package and retain the processing report, coordinates, reference frame, epoch and reported uncertainty. Record the orbit and clock product. Reprocess with Final products when available before adopting coordinates.

  4. Review before adopting a base coordinate
    Review antenna handling, convergence, residuals and uncertainties. Transform the accepted PPP solution to Mexico’s official horizontal frame, ITRF2008 at epoch 2010.0 (GRS80), per INEGI Article 10. Record the method and check equivalent height conventions before comparing with RTK. Account for the reference-base change at 3243 when comparing the RTK checks. CSRS-PPP uses precise satellite products independently of the RTK bases. Document acceptance for base use.

CSRS-PPP submission portal · CGS processing products and reference frames · CGS antenna handling guide · INEGI · Norma Técnica para el Sistema Geodésico Nacional, art. 10 (DOF, 23 Dec 2010)

Survey report

Weekly summary, three daily reports and the CSRS-PPP protocol.